Auto Shut-Down - Hitachi ZAXIS 135US-5B Operator's Manual

Hydraulic excavator
Table of Contents

Advertisement

Auto Shut-Down

d
WARNING: This function automatically stops
the engine. Take extra care on the work and work
environment when using this function.
When the auto shut-down function is turned ON, the engine
automatically stops after the preset time at the state in which
the pilot control shut-off lever is pulled. 30 seconds before
the engine stop, monitor (2) displays a message that engine
will be stopped and indicator (1) starts flashing. Also the
buzzer sounds. The buzzer sounds once at 30 seconds before,
then continuously sounds from 15 seconds. The engine
speed decreases to the idling speed, and then stops after 15
seconds. When the pilot control shut-off lever is pushed before
stopping the engine, the auto shut-down is disabled and the
engine will not stop.
IMPORTANT: Ensure the ON or OFF status of auto shut-
down indicator (1). If the indicator is ON, the auto shut-
down function will be activated.
Operating Condition
 The engine is running.
 The pilot control shut-off lever is in the LOCK position.
 Coolant and hydraulic oil temperature are not high.
 The muffler filter is not in regenerating process.
IMPORTANT:
 When the engine stops by the auto shut-down
function, turn the key switch to ACC or OFF once and
then turn it to START to restart the engine. Turn the
key switch OFF after auto shut-down when leaving
the machine for long period of time. Do not leave the
machine after auto shut-down. Failure to do so may
discharge the batteries.
 When the key switch is turned to OFF position while
the auto shut-down function is ON, the setting will
be reset. When it is required to keep the setting,
consult your nearest Hitachi dealer.
OPERATING THE MACHINE
5-9
1
2
MDAA-01-146EN
MDAA-01-286EN

Advertisement

Table of Contents
loading

This manual is also suitable for:

Zaxis 225us-5bZaxis 225uslc-5b090001300001

Table of Contents