Refueling - Hitachi ZAXIS 135US-5B Operator's Manual

Hydraulic excavator
Table of Contents

Advertisement

Refueling

1. Park the machine on a level surface. Lower the bucket to
the ground. Check the fuel level with fuel gauge (1).
If the fuel level is low, stop the engine. Refuel by
removing cap (2) on the fuel tank.
2. Remove cap (2) of filler port.
[Cap (2) unlock procedures]
 Release the key lock.
 Pull up handle (3) and turn handle (3)
counterclockwise for releasing cap (2) lock.
 Remove cap (2).
3. To avoid condensation, fill the tank at the end of each
day's operation. Tank capacity is as follows.
Model
ZX135US-5B
ZX225US-5B, 225USLC-5B
Do not fill the tank more than specified. Stop filling when
a yellow mark on fuel level gauge (4) becomes visible.
Position the oil filler gun so that the gun will not
encumber the movement of the level gauge (4) float.
4. Immediately after fueling, install and lock filler cap (2) to
prevent vandalism and loss.
5. Install cap (2) of filler port.
[Cap (2) lock procedures]
 If Install cap (2).
 Turn handle clockwise until cap (2) is locked, and
push down handle (3).
 Lock the key.
IMPORTANT:
 Take care not to allow dirt and/or water to enter the
fuel tank.
 Wipe off any spilled fuel.
 Never fail to remove filler cap (2) when refueling with
the automatic fueling device and be sure to stop
fueling when the yellow mark on the float of level
gauge (4) becomes visible.
MAINTENANCE
Tank Capacity
220 L
380 L
3
7-51
2
LOCK
MLBA-07-094
3
Yellow
Mark
1
MDAA-01-001
MDCN-07-022
UNLOCK
MLBA-07-093
M157-07-060