3. Always keep around the battery terminals clean to
prevent battery discharge. Check terminals for loose
and/or rust.
Coat terminals with grease or petroleum jelly to prevent
corrosion build up.

Replace Battery

IMPORTANT: Turn the battery disconnect switch to OFF
before replacing the battery.
This machine is equipped with two 12V batteries. Negative
terminal is connected to the ground.
If one battery is damaged on the 24V system, replace the
damaged battery with the same type of new battery. If a
maintenance free battery is damaged, replace it with new
maintenance free battery. Battery charger differs depending
on the type of battery. If improper battery is connected, the
battery is overloaded and possibly resulting in malfunction.