3. Press selector knob (2) to display Setting Menu screen
(5).
4. Rotate selector knob (2) to highlight Muffler Filter
Regeneration Inhibited (6).
5. Press selector knob (2) to display Muffler Filter
Regeneration Inhibited screen (7).
6. Rotate selector knob (2) to highlight
selector knob (2) to display Muffler Filter Regeneration
Inhibited screen (9).
7. Rotate selector knob (2) to highlight ON (10).
Confirmation screen is added.
8. Press selector knob (2) to turn Muffler Filter Regeneration
Inhibited ON. Press selector knob (2) again to turn
Muffler Filter Regeneration Inhibited OFF.
9. When ON is selected, the regeneration inhibited icon will
be displayed on the monitor. (Refer to 1-24)
f
NOTE: When the function is ON, the mark "" is displayed in
green. When the function is OFF, the mark "" is displayed in
gray.
IMPORTANT: When the machine is operated with the
muffler filter regeneration inhibited, the muffler filter
becomes clogged. When the muffler filter regeneration
request is displayed, move the machine to a safe
place. Perform the manual regeneration following the
specified procedure. Failure to do so may damage the
muffler filter. Refer to "Muffler Filter" section (1-25,
5-12) for the manual regeneration.