fully extended, this latch locks the assembly in the fully extended position. When you
depress the latch, you can release the inner member from the rest of the slide assembly.
C
B
Figure 2
Safety Latch
A. Inner Member
B. Safety Latch
C. Intermediate Member
Warning:
You must anchor the equipment rack to an unmovable support to prevent
it from falling over when the server is pulled on the slide assembly. The anchors must
be able to withstand a force of up to 113 kg (250 lbs). You must also consider the weight
of any other device installed in the rack.
Caution: After completing the rack mount installation, do not depress the safety latch
unless you are removing the chassis from the rack. The purpose of the safety latch is to
prevent the server from unexpectedly sliding out of the rack.
A
The inner member is the narrowest piece of the slide
assembly. The inner member is attached to the chassis.
The safety latch is located on the inner member.
The intermediate member slides into the inner member.
Checking the Slide Rail Kit
5