Download Print this page

Verify Transmitter Configuration - Emerson Rosemount 3051 Quick Start Manual

Pressure transmitter and dp flowmeters with wirelesshart protocol
Hide thumbs Also See for Rosemount 3051:

Advertisement

Quick Start Guide
Step 4: Verify transmitter configuration
Operation can be verified in four locations:
At the device via the Local Display (LCD).
By using the Field Communicator.
Via the Smart Wireless Gateway's integrated web interface.
Via AMS Wireless Configurator.
Verify transmitter configuration using LCD display
The LCD will display the output values at the same rate as the wireless update
rate. Refer to the Rosemount 3051 Wireless manual for error codes and other
LCD messages. Press and hold the Diagnostic button for at least five seconds to
display the TAG, Device ID, Network ID, Network Join Status, and Device Status
screens.
Searching for
Network
N E T w K
S R C H N G
Verify transmitter configuration using Field Communicator
For HART Wireless transmitter communication, a 3051 Wireless Transmitter
Device Descriptor is required. For connecting with a Field Communicator, refer to
Figure 1 on page
From the HOME screen, enter the Fast Key sequence
Device Dashboard Fast Keys
10
Joining Network
n e t w k
N E G O T
3.
Connected with
Limited Bandwidth
n e t w k
L I M - O P
May 2015
Connected
n e t w k
O K
3, 5

Advertisement

loading

This manual is also suitable for:

Rosemount 3051cf