7) FSEL0, 1 (FOUT frequency Select 0, 1) bits
The combination of these two bits is used to set the FOUT frequency.
Note: All frequencies are temperature compensated!

Table 23 FSEL bit

FSEL1
FSEL0,1
(bit 3)
0
0
Write / Read
1
1
8) CSEL0, 1 (Compensation interval Select 0, 1) bits
The combination of these two bits is used to set the temperature compensation interval.
Please refer to 8.9. Temperature Compensation Function
9) AF (Alarm Flag) bit
If set to "0" beforehand, this flag bit's value changes from "0" to "1" when an alarm interrupt event has occurred.
Once this flag bit's value is "1", its value is retained until a "0" is written to it.
Please refer to 8.5. Alarm Interrupt Function.
10) TF (Timer Flag) bit
If set to "0" beforehand, this flag bit's value changes from "0" to "1" when a wakeup timer interrupt event has
occurred. Once this flag bit's value is "1", its value is retained until a "0" is written to it.
Please refer to 8.6. Wakeup Timer Interrupt Function.
11) UF (Update Flag) bit
If set to "0" beforehand, this flag bit's value changes from "0" to "1" when a time update interrupt event has
occurred. Once this flag bit's value is "1", its value is retained until a "0" is written to it.
Please refer to 8.7. Time Update Interrupt Function.
12) AIE, TIE, UIE (Alarm, Wakeup Timer, Update Interrupt Enable) bit
In case of Alarm or Wakeup Timer or Update occurs AIE, TIE, UIE bit controls /INT output.
When a "1" is written to this bit, an interrupt signal is generated (/INT status changes from Hi-Z to low) .
When a "0" is written to this bit, no interrupt signal is generated.
Please refer to each function.

Table 24 AIE, TIE, UIE bit

Function
Alarm
Wakeup Timer
Update

8.2.5. SOUT Control Register

Table 25 SOUT Control Register

Address
Function
19
SOUT set1
1A
SOUT set0
1)
SOUT set1 register (19h)
By setting 69h =01101001b into SOUT set1 SOUT function becomes activated.
Other data than 69h makes SOUT function non active. Then SOUT becomes Hi-Z.
2) DCE bit ((Direct Control Enable), DC bit (Direct Control)
In case of DCE=1, DC bit Value is outputted at SOUT.
In case of DCE=0, register value Flag value is outputted at SOUT.
FSEL0
FOUT frequency
(bit 2)
0
32.768 kHz Output
1
1024 Hz Output
0
1 Hz Output
1
32.768 kHz Output
condition
Alarm time hit
Timer Count down to 0
Minute or Second update
Bit7
Bit6
Bit5
Bit4
SOE6
SOE5
SOE4
SOE7
DCE
DC
Page - 13
Default
Flag
AF
TF
UF
Bit3
Bit2
Bit1
SOE3
SOE2
SOE1
SRV
FS2
FS1
/INT interrupt control
AIE
TIE
UIE
Bit0
Read
Write
SOE0
FS0
ETM59E-05