Lp2 Probe Types - Renishaw LP2 Installation And User Manual

Probe system
Hide thumbs Also See for LP2:
Table of Contents

Advertisement

There are four versions of the LP2 probe.
Each version is best suited to particular
applications.
LP2 – For normal setting/inspection. The
metal eyelid protects the diaphragm in a hot
chip and coolant environment.
LP2H – With higher stylus pressure for long
or heavy styli, or where there is excessive
machine vibration.
LP2DD – LP2HDD – The double diaphragm
(DD) arrangement is recommended for
grinding machines and other applications
with particle-laden coolant. The LP2HDD is a
version with a higher stylus spring pressure,
similar to the LP2H.
1.
Stylus – M4 thread
2.
Metal eyelid
3.
Spring
4.
Diaphragm
5.
Rear O-ring
6.
M16 thread
7.
Stylus spring pressure adjustment
8.
Swarf deflector – essential for LP2DD
and LP2HDD when continually exposed
to hot chips.

LP2 probe types

LP2
LP2H
LP2DD
LP2HDD
Stylus spring pressure adjustment not available
LP2DD probes are available as original equipment,
or existing LP2 probes may be converted to the DD
2
1
3
4 4
8
standard using a conversion kit.
5
7
5 6
4
*