MadgeTech Bridge120 Product Information Card

Advertisement

Quick Links

Part Number
Range
Resolution
Accuracy
Memory
Sample Rate
Units
µ
V, mV,
V, Engineering Units specified through software
Required Interface Package
Baud rate
Typical Battery Life
Operating Environment
Material
Dimensions
0.8" x 1.7" x 2.7" (20mm x 43mm x 69mm)
Approvals
*Bridge120 Range, Resolution and Accuracy
Nominal Range
+10mV
Measurement Range
+15mV
Resolution
1µV
Accuracy
+0.25%FSR
Input Range
0 to 2.5V
Reference Voltage
2.5V
Battery Warning
WARNING: FIRE, EXPLOSION, AND SEVERE BURN HAZARD. DO NOT SHORT CIRCUIT, CHARGE,
FORCE OVER DISCHARGE, DISASSEMBLE, CRUSH, PENETRATE OR INCINERATE. BATTERY MAY
LEAK OR EXPLODE IF HEATED ABOVE 80°C (176°F).
Specifications subject to change.
1.800.561.8187
Bridge120
See Table Below*
32,767
20Hz to 12 hours
IFC110 or IFC200
57,600
25 days
–40°C to +80°C (-40°F to 176°F),
0%RH to 95%RH (non-condensing)
ABS plastic
CE Pending
+25mV
+100mV
+1000mV
+37.5mV
+120mV
+1200mV
2.5µV
5µV
50µV
+0.10%FSR
+0.05%FSR
+0.01%FSR
0 to 2.5V
0 to 2.5V
0 to 2.5V
2.5V
2.5V
2.5V
www.
Product Information Card
Bridge120-10
10mV, 20 Hz, Bridge Data Logger
Bridge120-25
25mV, 20 Hz, Bridge Data Logger
Bridge120-100
100mV, 20 Hz, Bridge Data Logger
Bridge120-1000
1000mV, 20 Hz, Bridge Data Logger
information@itm.com
.com
Bridge120
Red 485
Dark Blue Pantone 289
Light Blue 58% of Pantone 289

Advertisement

loading

Summary of Contents for MadgeTech Bridge120

  • Page 1 –40°C to +80°C (-40°F to 176°F), 0%RH to 95%RH (non-condensing) Material ABS plastic Dimensions 0.8” x 1.7” x 2.7” (20mm x 43mm x 69mm) Approvals CE Pending *Bridge120 Range, Resolution and Accuracy Nominal Range +10mV +25mV +100mV +1000mV Measurement Range +15mV +37.5mV...
  • Page 2 Insert the Software USB into an open USB port. If the autorun does not appear, locate the The Bridge120 data logger is designed to interface with and measure strain gauges and load drive on the computer and double click on Autorun.exe. Follow the onscreen instructions.

This manual is also suitable for:

Bridge120-10Bridge120-25Bridge120-100Bridge120-1000