HWAM woodburning stove and confident that it will give you much pleasure. To ensure optimum operation and safety, we recommend that the installation should be carried out by an authorised HWAM retailer or a fitter recommended by the retailer. For an overview of HWAM retailers, visit www.hwam.com under “Retailer locations”.
Page 6
European, national and local regulations must be observed in terms of the size and thickness of a non- combustible floor covering the floor in front of the combustion chamber opening. Ask your HWAM retailer for assistance. The combustion chamber opening is 40.6 cm wide.
Page 7
Connection to the chimney HWAM Classic 4 has both rear and top smoke outlet that can be connected to an approved steel chimney on top or directly out at the rear to a brick chimney. If the stove is connected with un uninsulated steel chimney, there must be a distance of 225 mm from the inflammable wall to the uninsulated steel chimney.
Page 8
sealing (8) is placed down into the smoke outlet socket (drawing A1). At the same time a cushion (9) made out of the stove kit delivered with the baking section is placed round in the edge of the coo- king holes (drawing A2). Then the baking section (5) is placed on top of the stove so the smoke inlet sockets of the baking section are standing down in the smoke outlet as well as in the cooking holes on top of the stove.
Page 9
If the stove has not been used for a longer period, it is important to check that the chimney pipe is not blocked. It is possible to connect several devices to the same chimney. However, it is important to first check the applicable rules.
– IrIng manual wood Your first heating session The lacquer will be fully hardened after the stove has been used, and the door and the ashpan should be opened very carefully as there will otherwise be a risk that the gaskets will stick to the lacquer. In addition the lacquer may initially give off an unpleasant odour, so make sure that the room is well ventilated.
Page 11
(2) in the door is regulated down to half open. When there are visible yellow flames again, the air control lever (3) is pushed back to middle position. When in continuous use, no further re- gulation is necessary. This is done by the HWAM Autopilot™giving an even, constant burning. But if ®...
Insufficient firing If the fireproof materials in the combustion chamber are blackened after a fire, then the stove is polluting, and the HWAM Autopilot™ is malfunctioning. It will be necessary, therefore, to open the ®...
aIntenance Maintenance Any maintenance of the stove should only be carried out when it is cold. Daily maintenance is limited to vacuum cleaning the stove externally, using the soft brush attachment. You can also dust the stove using a dry, soft cloth or brush, but on a cold stove only. Once a year, the stove should be thoroughly serviced.
Stop using the stove and contact the retailer. At interruptions that you cannot yourself rectify, you should contact the retailer. eclaratIon oF erFormance The DoP can be downloaded from our website via the following link: www.hwam.com/dop/classic4 Page 14 of 16 pages...
• Always dispose of items in a way that is as sustainable as possible and that is in line with the current environmental protection, reprocessing/recycling and disposal technology HWAM A/S • Nydamsvej 53 • DK-8362 Hørning Page 15 of 16 pages...
Need help?
Do you have a question about the Classic 4 and is the answer not in the manual?
Questions and answers