SECTION 5

COMPLETION PROCEDURES

REMOTE CONTROL
RE-PROGRAMMING
All call/send controls are factory programmed. In
the event that the remote call/send controls need to
be re-programmed, it is essential to program both
controls in one programming cycle.
1. Start with the red "On/Off" switch in the "Off"
position.
2. Disconnect the 6-pin and 8-pin chair wire
harness from the chassis.
3. Press and hold the install switch (located on
the top of the chassis) in either direction.
4. Turn the red "On/Off" switch to the "On"
position. Wait for the circuit board to beep
and then release the install switch.
5. The lift will begin to beep rapidly, advising
that the first remote is ready to be
programmed.
6. Making sure that the remote is pointed at one
of the IR sensors on the chassis, press and
release the "Up" or "Down" button of the first
remote. The first remote is now programmed.
7. Press and release the "Up" or "Down" button
on the second remote. The second remote is
now programmed.
8. Upon completion, two beeps will indicate
that both remotes have been successfully
programmed.
9. Turn the "On/Off" switch to the "Off"
position.
PINNACLE STAIR LIFT: SECTION 5
COMPLETION PROCEDURES
10. Connect the 6-pin and 8-pin chair wire
harness to the chassis and then turn the red
"On/Off" switch back to the "On" position.
11. Test each remote in both the up and down
directions.

TEST ARMREST CONTROL

SWITCH
1. Ensure that the stair lift travels correctly by
operating the armrest control switch while
standing in front of it.
2. Press the switch in the upstairs direction
to move up. The lift will begin to smoothly
accelerate upward. The lift will continue to
move upward as long as the switch is pressed.
3. Release the switch and the lift will come to an
immediate stop.
4. Press the switch in the downstairs direction
to move downward. The lift will begin to
smoothly accelerate downwards.
5. Release the switch and the lift will come to an
immediate stop.
6. Run the lift all the way up and down the rail
to ensure that the top of the seat back has at
least a 1/2" in clearance from the wall and any
obstructions.
WARNING
!
Do not ride on the chassis or lift until the
installation is complete.
SL600 PINNACLE STAIR LIFT: