Email Alerts; Hard Disk Drive (Hdd) Replacement - Verizon Volicon MIP Admin Manual

Table of Contents

Advertisement

Email Alerts

7.5
The RAID controller can be set to send out email alerts. Click on <Tools>→<Monitor Configure
Alerts>. Volicon, a division of Verizon Digital Media Services recommends limiting emails to the most
Critical and Fatal, to minimize the number of emails sent by the system.
Click the <Mail Server> tab to setup the outgoing mail server and the <Email> tab to enter one or
more recipient email addresses.

Hard Disk Drive (HDD) Replacement

7.6
To replace an HDD on the hot swappable disk array, first remove the faulty bad drive and then insert
a new replacement HDD. The RAID controller will automatically start rebuilding the array.
If the controller is reporting multiple drive failures, try reseating the hot swappable drives first.
AG-7.2.B1-092414 • Restricted - customer use only
Figure: RAID Email Alerts