Snmp Notification; Mib Variables - Verizon Volicon MIP Admin Manual

Table of Contents

Advertisement

SNMP NOTIFICATION

14
MIP sends SNMP notifications to external systems (e.g., your Network Management System (NMS))
using the Alert Notification variables shown in the "SNMP Notification Settings" Table. You must
configure the IP addresses of your NMS stations in MIP to enable this capability.
MIB definitions are common across all Observer products.

MIB Variables

14.1
SNMP V2 MIB variables with definitions are listed in the "EncoderTraps_v2.mib" file or a similar *.mib
file located on the MIP server in the "Program Files\Volicon\docs" directory. The MIB file should be
used in addition to the "MIB Variables table" below.
The MIP can send SNMP V2 trap messages both for media related alerts that create fault clips and for
system critical events that do not generate clips.
Alert Variable Names (in
MIB)
volEncoder
volEncoderName
Octet String
volEncoderHostname
Octet String
volAlertClipID
Integer
volAlertDescription
Octet String
volAlertClipRef
Octet String
OID Strings
PREFIX =
1.3.6.1.4.1.23522.1
PREFIX.2
PREFIX.3
PREFIX.11.1
PREFIX.11.2
PREFIX.11.3
131
Description
Probe Server Name OID type and prefix for
OIDs below.
Name of Encoder which detected the alert.
(Names) configured during installation and
usually not changed by the user
Probe server Hostname, IP or DNS name. The
Hostnames should be unique within servers on
the NMS monitored network.
Generated with each new event (e.g., media
defect) to identify it.
Textual description of the alert.
Alert clip ID and URL for its location on the web
server e.g., http://MIP-
url.com/clip_view.php?id=158079.