Minimum speed OUT 1 in %
Data
Regulation range
MN1
3
.. 1
Minimum speed OUT 2 in %
Data
Regulation range
MN2
3
.. 1
Increase 10%
Data
Regulation range
INC
1. C .. 2 . C
P13

: MINIMUM TEMPERATURE LIMITATION

' TO SET
This parameter will be shown with P13 only for version
with variable collector pump speed, while it will be
shown with P12 for all the other versions.
The parameter 'Minimum Temperature Limitation' on collector is
used to manage the Minimum Temperature Thermostat used for
Default
activation of the collector pumps.
3
This thermostat stops the pumps operation whenever on the
relevant panel is measured a temperature lower than the one
set in this parameter. The function 'Minimum Temperature
Limitation' is not active when in Manual operation mode in
Default
A C operation or in case the pumps activation is caused by the
intervention of Recooling or similar functions.
3
Default
2. C
3
WARNING!
AFTER SELECTIN PARAMETER P13 PRESS
T E '
' KEY.