Setting Of Collector Pump Speed - Ariston ELIOS 25 Manual

Digital control unit for thermal solar systems
Table of Contents

Advertisement

P12

: SETTING OF COLLECTOR PUMP SPEED

WARNING!
This parameter is available only for version with variable
collector pump speed.
OUT 1 e OUT 2 are semiconductor solid state relays
suitable to drive the speed of a circulation pump. In
case they are used to drive other electric devices (i.e.
motorized valves) P12, %MN1 and/or %MN2 must be
set to 100% (maximum speed).
This parameter can be selected by the 'menu' key and permits
to set the data which will control the speed of the collector
pumps connected to OUT1 and OUT2.
The working principle which regulates solar collector pump
speed variation is very much linked to the need to keep the
difference in temperature between the solar collector and the
boiler as constant as possible (T).
Since it is a well-known fact that as incidental solar radiation
increases the T also tends to increase one way of decreasing
the T whilst maintaining incidental solar radiation constant is
to reduce the amount of time that the uid transits within the
collector or rather to increase uid transit speed by increasing
the number of solar collector pump rotational speed.
Using the P12 parameter it is possible to set both the minimum
work speed of the solar collector pump as a percentage and
the variation in temperature required to increase solar collector
pump speed by 1
in relation to the T (INC parameter).
The power unit is delivered already set for an optimal
operation.
The preset data can only be changed by quali ed staff.
AFTER SELECTIN PARAMETER P12 PRESS
T E '
PRESS ARRO S '
' and '
COLLECTOR PUMP PARAMETERS:
MINIMUM SPEED OUT 1 IN
MINIMUM SPEED OUT 2 IN
INCREASE 1
PRESS '
' TO C AN E T E SELECTED PARAMETER;
T E PARAMETER ILL START LINKIN .
3
' KEY.
' TO CYCLICALLY SCROLL
' MN1 3 '
' MN2 3 '
' INC 2. C '