Recooling Temperature
Data
Regulation range
TR
C .. (TM3+5) C
WARNING!
It is not possible to set the value of the Recooling
Temperature (TR) at a value which is equal or lower
than the value of the highest Maximum Temperature.
' and '
' TO SET
Default
C
34
The value of the Recooling Temperature (TR) is linked to
the value of the highest Maximum Temperature +1°C.
In order to lower the Recooling Temperature (TR)
below the value of the maximum Temperatures
already set, rst of all lower the value of the maximum
Temperature(s), then change the Recooling Temperature
(TR). Should any Maximum Temperature be increased to
a value which is higher than the value of the Recooling
Temperature (TR), this is automatically set at the value
of the highest maximum temperature +1°C.
The same shall be considered as regards the Recooling
Temperature (TR) with reference to the integration
temperature (TAH).
Recooling Temperature (TR) Differential
Data
Regulation range
TR
C .. 15 C
Activation / Deactivation of the Recooling function
Data
Regulation range
RECEN
.. 1
Note:
' 0 ' indicates the Recooling function is
deactivated, whereas ' 1 ' indicates it is
activated.
Default
C
Default
1