General Information; Warranted Information; General Conditions For Safe Use; Ce Label - CEL-MAR ADA-1021 User Manual

Rs-232 to current loop converter
Table of Contents

Advertisement

ADA-1021

1. GENERAL INFORMATION

Thank you for your purchase of CEL-MAR Company product. This product has been completely tested and is covered by a two year
warranty on parts and operation from date of sale.
If any questions or problems arise during installation or use of this product, please do not hesitate to contact Technical Support at +48
41 362-12-46 or e-mail support@cel-mar.pl.

1.1. WARRANTED INFORMATION

The ADA-1021 converter is covered by a two year warranty from date of sale. In case of being damaged it will be repair or the
damaged component will be replace. The warranty does not cover damage caused from improper use, materials consumption or any
unauthorized changes. If the product does not function (is damaged), or not operate in accordance with the instructions, will be
repaired.
All warranty and no warranty repairs must be returned with paid transport and insuring to the CEL-MAR Company.
CEL-MAR Company under no circumstances won't be responsible for ensuing damage from improper using the product or as a result
of random causes: the lightning discharge, the flood, the fire and the like.
CEL-MAR Company is not be held responsible for damages and loss including: loss of profits, loss of data, pecuniary losses ensuing
from using or the impossibility of using this product.
In specific cases CEL-MAR Company discontinue all warranties and in particular do not follow the user manual and do not accept
terms of warranty by the user.

1.2. GENERAL CONDITIONS FOR SAFE USE

The device should be installed in a safe and stable places (eg, electroinstallation cabinet), the powering cable should be arranged so
as not to be exposed to trampling, attaching, or pulling out of the circuit.
Do not put device on the wet surface.
Do not connect devices for nondescript powering sources,
Do not damage or crush powering wires.
Do not make connection with wet hands.
Do not adapt, open or make holes in casings of the device!
Do not immerse device in water or no other liquid.
Do not put the fire opened on device sources: candles, an oil lamps and the like.
Complete disable from the supply network is only after disconnecting the power supply circuit voltage.
Do not carry out the assembly or dis-assembly of the device if it is enabled. This may result to short circuit and damage the device.
The device can not be used for applications that determine human life and health (eg. Medical).

1.3. CE LABEL

The CE symbol on the device CEL-MAR means compatibility with electromagnetic compatibility Electromagnetic
Compatibility Directive EMC 2014/30/WE. Declaration of Conformity is available by contact with Technical Service
(email: support@cel-mar.pl; phone: +48 41 362-12-46).

1.4. ENVIRONMENTAL PRESERVATION

This sign on the device inform about putting expended device with other waste materials. Device should send to the
recycling. (In accordance with the act about the Electronic Appliance Expended from day 29 of July 2005)

1.5. SERVICE AND MAINTENANCE

The ADA-1021 converter does not require the servicing and maintenance.
Technical support is available at number +48 41 362-12-46 in 8.00-16.00, from Monday to Friday or e-mail support@cel-mar.pl.

1.6. PACK CONTENTS

The converter is delivered with the user manual.

2. PRODUCT INFORMATION

2.1. PROPERTIES

● Operating on 4-wire network in Current Loop standard
● Conversion TX, RX signals of RS232 interface,
● Baud rate up to 38,4 Kbps (depending on the length of the line),
● Transparent for all protocols: MODBUS, DNP, PROFIBUS and other,
● Any format of transmission frame,
● 0-20mA Current Loop active/passive transmitter, active/passive receiver.
● External power supply from 10 to 30 VDC (standard) stabilized
● ~3kV= optoisolation in signal channel between RS232 and Current Loop interface,
● 1kV= or 3kV= galvanic isolation between RS232 interface and power supply,
● 1kV= or 3kV= galvanic isolation between Current Loop interface and power supply,
● Connection Current Loop line and power supply via screw terminal block,
● Connection RS-232 interface via DB-9F connector by the use of extension cable,
● Integrated short circuit protection and over-voltage protection on Current Loop lines,
● Protection against power supply reverse connection,
● DIN 43880 standard - mounting in typical electro-installation unit,
● Rail mounting according to DIN35 / TS35 standard,