Appendix A: Installation And Operation Of Nav-View; Nav-View Computer Requirements; Install Nav-View; Setting Up Nav-View - Aceinna IMU383 Series User Manual

Hide thumbs Also See for IMU383 Series:
Table of Contents

Advertisement

IMU383ZA Series User's Manual
________________________________________________________________________

Appendix A: Installation and Operation of NAV-VIEW

NAV-VIEW has been designed to allow users to control all aspects of the compatible Aceinna
IMU product families. Note some of the functions described are not available on all of the
product families (for example, the AHRS or INS functionality does not apply to an IMU). NAV-
VIEW version 3.5.2 or higher is required.

NAV-VIEW Computer Requirements

The following are minimum requirements for the installation of the NAV-VIEW Software:
CPU: Pentium-class (1.5GHz minimum)
RAM Memory: 500MB minimum, 1GB+ recommended
Hard Drive Free Memory: 20MB
Operating System: Windows 7 and 10
Properly installed Microsoft .NET 2.0 or higher

Install NAV-VIEW

To install NAV-VIEW onto your computer:
1. Go to
https://www.aceinna.com/manuals
Click the link and download the latest version of the software.
2. Locate the downloaded version of Nav-View on your computer and unzip the file. In the
extracted folder click the "setup.exe" file.
3. Follow the setup wizard instructions. You will install NAV-VIEW and .NET 2.0.
WARNING
Do not reverse the power leads!
damage the unit. Although reverse power protection is provided, ACEINNA is not
responsible for resulting damage to the unit should the reverse voltage protection
electronics fail.

Setting up NAV-VIEW

With the IMU383 Series product powered up and connected to your PC serial port, open the
NAV-VIEW software application.
1. NAV-VIEW should automatically detect the IMU383 Series product and display the serial
number and firmware version if it is connected.
2. If NAV-VIEW does not connect, check that you have the correct COM port selected. You
will find this under the "Setup" menu. Select the appropriate COM port and allow the
unit to automatically match the baud rate by leaving the "Auto: match baud rate"
selection marked.
3. If the status indicator at the bottom is green and states,
the status indicator doesn't say connected and is red, check the connections between the
Doc# 7430-1398-01
and locate the link to the Nav-View zip file.
Reversing the power leads to the IMU383 Series can
Downloaded From
Oneyac.com
, you're ready to go. If