IMU383ZA Series User's Manual
________________________________________________________________________
Dynamic Range
+/-62.5°/sec
+/-125.0°/sec
+/-250.0°/sec
+/-500.0°/sec
+/-1000.0°/sec
The digital low-pass filter configuration register has address 0x38 and described in Table 18.
Note: these settings apply only to data output via the unit SPI port and do not affect the low-level
UART output port.
Table 18 Sensor Scaling/Digital Low-Pass Filter Register
Bits
[7:0 ]
The digital low-pass filter register sets the type and cutoff frequency of the filter applied to the
scaled sensor data. The default setting is a 5 Hz Bartlett filter; to switch to a 20 Hz Butterworth
filter, the master sends 0xB840. Figure 10 shows the output response of the different Bartlett
filter settings.
Doc# 7430-1398-01
Table 17 Rate-Sensor Scaling Factor
Scale Factor
Signal Limit
400 LSB/( °/sec )
+/-80.0 °/sec
200 LSB/( °/sec )
+/-160.0 °/sec
100 LSB/( °/sec )
+/-200.0 °/sec
50 LSB/( °/sec )
+/-400.0 °/sec
25 LSB/( °/sec )
+/-600.0 °/sec
(Base Address: 0x38), Read/Write
Description (Default: 0x0206)
Digital Low-Pass Filter
0x00 (0): Unfiltered
0x03 (3): 40 Hz Bartlett
0x04 (4): 20 Hz Bartlett
0x05 (5): 10 Hz Bartlett
0x06 (6): 5 Hz Bartlett (default)
0x30 (48): 50 Hz Butterworth
0x40 (64): 20 Hz Butterworth
0x50 (80): 10 Hz Butterworth
0x60 (96): 5 Hz Butterworth
Downloaded From
Oneyac.com
Over-Range Limit
+/-62.5 °/sec
+/-125.0 °/sec
+/-220.0 °/sec
+/-440.0 °/sec
+/-660.0 °/sec
Page 23