Set Fields Command - Aceinna IMU383 Series User Manual

Hide thumbs Also See for IMU383 Series:
Table of Contents

Advertisement

IMU383 Series User's Manual
________________________________________________________________________
numFields*4 -1
field...Data
Write Fields Response
Write Fields ('WF' = 0x5746)
Preamble
Packet Type
0x5555
0x5746
The unit will send this packet in response to a write fields command if the command has
completed without errors.
WF Payload Contents
Byte Offset
Name
0
numFields
1
field0
3
field1
...
...
numFields*2 – 1
Field...
7.7.2

Set Fields Command

Set Fields ('SF' = 0x5346)
Preamble
Packet Type
0x5555
0x5346
This command allows the user to set the unit's current configuration (SF) fields immediately
which will then be lost on power down. NumFields is the number of words to be set. The field0,
field1, etc. are the field IDs that will be written with the field0Data, field1Data, etc., respectively.
This command can be used to set configuration fields. The unit will not set calibration or
algorithm fields. If at least one field is successfully set, the unit will respond with a set fields
response containing the field IDs of the successfully set fields. If any field is unable to be set, the
unit will respond with an error response. Note that both a set fields and an error response may be
received as a result of one set fields command. Attempts to set a field with an invalid value is one
way to generate an error response. A table of field IDs and valid field values is available in
Section 7.1.
SF Payload Contents
Byte Offset
Name
0
numFields
1
field0
3
field0Data
5
field1
7
field1Data
...
...
numFields*4 -3
field...
numFields*4 -1
field...Data
Doc# 7430-1398-01
U2
-
-
Length
Payload
1+numFields*2
<WF payload>
Format
Scaling
Units
U1
-
-
U2
-
-
U2
-
-
U2
-
-
U2
-
-
Length
Payload
1+numFields*4
<SF payload>
Format
Scaling
Units
U1
-
-
U2
-
-
U2
-
-
U2
-
-
U2
-
-
U2
-
-
U2
-
-
U2
-
-
Downloaded From
Oneyac.com
The last field ID's data to write
Termination
<CRC (U2)>
Description
The number of fields written
The first field ID written
The second field ID written
More field IDs written
The last field ID written
Termination
<CRC (U2)>
Description
The number of fields to set
The first field ID to set
The first field ID's data to set
The second field ID to set
The second field ID's data to set
...
The last field ID to set
The last field ID's data to set
Page 44