Bender LINETRAXX CTBC series Quick Manual

Bender LINETRAXX CTBC series Quick Manual

Ac/dc sensitive measuring current transformer cores

Advertisement

Quick Links

LINETRAXX® CTBC series
AC/DC sensitive measuring current
transformer cores

Intended use

The AC/DC sensitive measuring current transformer
cores of the CTBC series can only be used in combi-
nation with one of the follwing devices:
• MRCDB300 series (see manual D00343)
• CTUB100 series (see manual D00362)
• RCMB300 series (see manual D00372)
The measuring current transformer cores convert
system leakage and fault currents into a signal to be
processed by the devices mentioned above. The
measuring current transformers can be used in DC,
AC, and 3(N)AC systems. The devices are suitable for
detecting fault currents with smooth DC compo-
nents. CTBC...P are insensitive to load currents due
to full magnetic shield, can be used for high short-
term system-related load currents.

Dimension diagrams

a
b
c
d
i
...
CTUB10
-CTBC20(P)/CTBC35(P)
Dimensions (mm), tolerance: ±0.5 mm
CTBC
a
b
20(P)
75
45
35(P)
94
54
60(P)
126
70
120(P)
210(P)
CTBC-series_D00336_02_M_XXEN/09.2020
a
g
h
j
k
d
CTUB10
c
d
e
83
40
ø 20
100
58.4
ø 35
137
84.5
ø 60
211
139
ø 120
324
277
ø 201

General safety instructions

Part of the device documentation in addition to this
manual is the enclosed „Important safety instructi-
ons for Bender products".
Installation, connection and commissioning are to
be carried out by electrically skilled persons only! It is
essential to follow the existing safety instructions.
I
This symbol indicates a high risk of danger
that will result in death or serious injury if
not avoided.
I
This symbol indicates a low-level risk that
can result in minor or moderate injury or
damage to property if not avoided.
i
This symbol refers to information that is de-
signed to help you make the best use of the
product.
g
b
c
h
l
i
j
...
-CTBC60(P)
f
g
h
ø 60
46
37
ø 79.5
45
46
ø 111
55
57
ø 188
66
96
ø 302
68
153
g
c
d
j
...
CTUB10
-CTBC120/210(P)
i
j
k
6
60.5
5
60.5
16
78.5
23
7.5
96
7.5
113
l
i
l
1.5
17
26

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LINETRAXX CTBC series and is the answer not in the manual?

Questions and answers

Summary of Contents for Bender LINETRAXX CTBC series

  • Page 1 CTBC series can only be used in combi- manual is the enclosed „Important safety instructi- nation with one of the follwing devices: ons for Bender products“. Installation, connection and commissioning are to • MRCDB300 series (see manual D00343) be carried out by electrically skilled persons only! It is •...
  • Page 2 LINETRAXX® CTBC series Mountings CTBC20(P) 31.4 2 x ø 5.5 CTBC35(P) 49.8 2 x ø 5.5 CTBC60(P) 3 x ø 6.5 CTBC120(P) 4 x ø 6.5 CTBC210(P) 4 x ø 5.5 CTBC20(P), CTBC35(P) CTBC60(P) CTBC120(P) ... CTBC210(P) Assembly Slide the electronic module onto the plug contacts of the measuring current transformer. In combination with devices of the MRCDB300 series, an offset calibration is mandatory at the final instal- lation site before the initial commissioning.
  • Page 3 LINETRAXX® CTBC series Installation instructions of measuring CT ! Device damage due to high induction aution currents! High currents can be induced into the conductor loop due to the AC/DC sensitive meas- uring technology used. Do not route protective conductors and low-resistance conductor loops through the measuring current transformer! All current-carrying cables must be routed through the meas- ! Device damage due to interference...
  • Page 4 Nachdruck und Vervielfältigung Reprinting and duplicating nur mit Genehmigung des Herausgebers. only with permission of the publisher. Bender GmbH & Co. KG Bender GmbH & Co. KG Postfach 1161 • 35301 Grünberg • Deutschland PO Box 1161 • 35301 Grünberg • Germany Londorfer Str.

This manual is also suitable for:

Linetraxx ctbc 20Linetraxx ctbc 20pLinetraxx ctbc 35Linetraxx ctbc 35pLinetraxx ctbc 60Linetraxx ctbc 60p ... Show all

Table of Contents