NB: Commissioning
The retro-reflective sensor is supplied ready to operate (plug and play)
set at the max. sensing range. This is sufficient if the retro-reflective
sensor can operate with maximum excess gain (highest contrast). The
following setting procedures should only be necessary in less straight-
forward applications, for example if partly transparent objects must be
detected.

Setting of the sensitivity with stationary objects

Activate the programming mode of the unit.
1
Press for about 2s until the red LED flashes.
The red LED goes out; the yellow and green LEDs flash alternately.
The unit is in the programming mode.
Set the sensitivity with object.
2
The yellow and green LEDs go out for approx. 1s,
then flash again alternately.
8
Press once.