Adjustment Aid; Commissioning; Setting Of The Sensitivity With Stationary Objects - IFM Electronic efector 200 OG laser Operating Instructions Manual

Retro-reflective sensor
Hide thumbs Also See for efector 200 OG laser:
Table of Contents

Advertisement

Do not align the beam towards the fixing screw of the prismatic reflector�
Mount the unit so that the mounting position cannot change (in particular
avoid high vibrations!)�
Laser units with a very small light spot diameter are highly focussed; the
slightest change in the mounting position will result in misalignment�

Adjustment aid

To make alignment easier the intensity of the light spot is increased during the
setting until it becomes clearly visible� In the operating mode (after step 3 of the
setting) the transmitted light is set to normal intensity�

Commissioning

The retro-reflective sensor is supplied ready to operate (plug and play) set at the
max� sensing range� This is sufficient if the retro-reflective sensor can operate
with maximum excess gain (highest contrast)� The following setting procedures
should only be necessary in less straightforward applications, for example if partly
transparent objects must be detected�

Setting of the sensitivity with stationary objects

Activate the programming mode of the unit without object�
1
Press for about 2 s until the red LED flashes�
>
The red LED goes out; the yellow and green LEDs flash alternately�
>
The unit is in the programming mode�