Writing Of Ddc Data - Sony VPL-F635HZ Service Manual

Table of Contents

Advertisement

2-6-7. Writing of DDC Data

1. Connect the power cord and set this unit to standby state.
2. Press the [I/O] button on this unit.
The lamp lights and the image is displayed.
3. Double-click QuickAccess3.exe to start the application.
4. Select a target model on the Model pull-down menu.
5. Select Read from Projector on the Read/Write pull-down menu.
6. Select DDC on the Data Type pull-down menu.
7. Click the [Next] button.
8. Click the [Browse...] button.
The file selection window is displayed.
9. Set the destination file for the writing data as below.
DDC data for INPUT A: BPJ_WUXGA_Pixie_VGA_0_**.dat
DDC data for INPUT B: BPJ_WUXGA_Pixie_DVI_1_**.dat
DDC data for INPUT C: BPJ_WUXGA_Pixie_HDMI_2_**.dat
n
. The writing is not required for INPUT D. The DDC data of INPUT C is used as that of INPUT D.
. ** means version.
10. Click the [Next] button.
11. Select the serial port used for connecting PC on the Serial Port pull-down menu.
Upper line: Serial port number used for connecting PC
Lower line: 38400 (not selectable)
12. Click the [Next] button.
The window displaying the file path, model name written in file, unit serial, serial number, and DDC
ID is displayed.
13. Click the [OK] button.
The writing starts. Completed is displayed after completed.
14. Disconnect the power cord from this unit.
15. Click the [Complete] button.
VPL-FHZ65
2-23 (E)

Advertisement

Table of Contents
loading

Table of Contents