Writing 3Dgamma/Lookuptable/Ddc; Lck/Ogmtable/Csmatrixtable Data; How To Obtain The 3Dgamma/Lookuptable/Ddc/Lck/Ogmtable/Csmatrixtable Data From The Board - Sony VPL-VW70 Service Manual

Hide thumbs Also See for VPL-VW70:
Table of Contents

Advertisement

1-6-3. Writing 3DGamma/LookUpTable/DDC/

LCK/OGMTable/CSMatrixTable Data

Use the dedicated application "Quick Access" for writing
the data.
Application name: 3DGamma Quick Access
Filename:
QuickAccess.exe
Version:
7.90 or later
1. Connect the PC to VW70 with the RS-232C cross
cable.
2. Turn the power on to the projector.
3. Double-click on "QuickAccess.exe" to launch the
application.
4. Select "VPL-VW70" from the [Model] pull-down
menu.
5. Select "Load" from the [Load/Save] pull-down menu.
6. Select the data type (3DGamma/LookUpTable/DDC/
LCK/OGMTable/CSMatrixTable) from the [3dgm/
Lut] pull-down menu.
7. Click on [Next].
8. Press the [Browser] button and specify the file to
write.
9. Click on [Next].
10. Set the COM Port and switch the baud rate to 38400.
11. Click on [Next].
12. When the dialog box appears prompting your confir-
mation, click on [OK].
13. Writing has finished when "Completed." appears.
14. Click on [End].
* See Technical Memo DPPJ04-044R for more details.
VPL-VW70
1-6-4. How to Obtain the 3DGamma/
LookUpTable/DDC/LCK/OGMTable/
CSMatrixTable Data from the Board
For reading out the captioned data, use the dedicated
application program Quick Access.
Application name: 3DGamma Quick Access
Filename:
QuickAccess.exe
Version:
7.90 or later
1. Connect the PC to VW70 with the RS-232C cross
cable.
2. Turn the power on to the projector.
3. Double-click on "QuickAccess.exe" to launch the
application.
4. Select "VPL-VW70" from the [Model] pull-down
menu.
5. Select "Save" from the [Load/Save] pull-down menu.
6. Select the data type (3DGamma/LookUpTable/DDC/
LCK/OGMTable/CSMatrixTable) from the [3dgm/
Lut] pull-down menu.
7. Click on [Next].
8. Click the [Browse] button to enter the filename of data
to be saved.
9. Click on [Next].
10. Set the COM Port and switch the baud rate to 38400.
11. Click on [Next].
12. When the dialog box appears prompting your confir-
mation, click on [OK].
13. Obtaining has finished when "Completed." appears.
14. Click on [End].
1-21

Advertisement

Table of Contents
loading

Table of Contents