Led Indicators - ABB ESAB W82 Integration Manual

Robot for welding machine, interface w82 integrated and w82 anybus
Table of Contents

Advertisement

LED indicators

The fieldbus board is equipped with four bi-colour LED's at the front of the board
showing the status.
LED 1 and 4 are reserved for future use.
LED 2 - Network status
Colour
Frequency
Off
-
Green
Steady on
Green
Flashing
Red
Steady on
Red
Flashing
LED 3 - Module status
Colour
Frequency
Off
-
Green
Steady on
Green
Flashing
Red
Steady on
Red
Flashing
Watchdog LED
The fieldbus board includes a bi-colour watchdog LED, indicating the status of the
module.
Colour
Frequency
Red
-
Red
1 Hz
Red
2 Hz
Red
4 Hz
Green
1 Hz
Green
2 Hz
cr09_01_2
Description
Not powered / Not on line
Link OK, On line, Connected
On line, Not connected
Critical link failure
Connection timeout
Description
No power to device
Device operational
Data size bigger than configured
Unrecoverable fault
Minor fault
Indication
Unspecified internal error, or running in bootloader mode
RAM failure
ASIC or FLASH failure
DPRAM failure
Module initialised and running OK
Module not initialised
- 15 -