11.7
Declare the cells
The MMC XCELLU, Object "Cells", is used to declare the cells.
A cell must be a group of base stations with adjacent coverage. The maximum number of base
stations per cell is 8 (you are advised to configure only 6, with a view to expansion in order to
increase traffic flow). It may be necessary to declare several cells. The "Registration zone" is
always 0. In multisite configuration, if the coverage areas overlap, you are advised to select
different cell numbers for each of the sites.
Object=Cells
---------------------------------------------------------------------------
Type of cell=DECT
---------------------------------------------------------------------------
Registration zone
Operation complete
Page 11-193
CORDLESS TOPOLOGY
--->
=0.
10/2008
Action=Display
Cell=3..