Optional Settings Explained
THE FOLLOWING SETTINGS ARE OPTIONAL AND IN MOST CASES NEED
NOT BE ADJUSTED.
Feature 01 – Pairing To SmartHub: This function is used to connect the thermostat to the
Smart Hub .
Feature 02 - Switching Di erential: This function allows you to increase the switching
di erential of the thermostat. The default is 1°C which means that with a set temperature of
20°C, the thermostat will switch the heating on at 19°C and o at 20°C. With a 2°C di erential,
the heating will switch on at 18°C and o at 20°C.
Feature 03 - Frost Protect Temperature: This is the temperature maintained when the
thermostat is in Frost Mode. The range is 07 - 17°C. The default is 12°C and is suitable for most
applications.
Feature 04 – Output Delay: To prevent rapid switching, an output delay can be entered.
This can be set from 00 - 15 minutes. The default is 00 which means there is no delay.
Feature 05 – Temperature Up/Down Limit: This function allows you to limit the use of the up
and down temperature arrow keys. This limit is also applicable when the thermostat is locked
and so allows you to give others limited control over the heating system.
Feature 06 – Sensor Selection: On SmartStat, you can select which sensor should be used.
You can select between air temperature only, oor temperature, or both. When you enable
both sensors, the oor sensor is used as a oor limiting sensor and is designed to prevent the
oor from overheating.