4 STANDARD USE CASE

Here you can see a standard use case of the 100/1000BASE-T1 MediaConverter:
Figure 4-1: Example of a use case
MC
DUT
DIP Switch 1:
Master/Slave
must be configured as Slave, DIP Switch 1 must be OFF [down], and vice versa
DIP Switch 2:
100/1000 speed
is a 100BASE-T1 connection DIP Switch 2 must be OFF [down] and vice versa
DIP Switch 3:
Legacy/IEEE mode
A0 (Only 1000BASE-T1) then the DIP Switch 3 must be OFF [down]. If it is any
other IEEE 1000BASE-T1 conform PHY the DIP Switch must be ON [up]
DIP Switch 4:
Frame Generator-Mode, the DIP Switch must be ON [up], in this case, the device
no longer works as a converter
100/1000BASE-T1 MediaConverter hMTDUser Manual
setting, is dependent on the DUT. If DUT is Master, MC
setting is dependent on the speed of the DUT. If it
Frame Generator
Media Converter
Device Under Test
setting: If the PHY of the DUT is a Marvell PHY
function, always must be OFF [down]. Only in