CONTENT GENERAL INFORMATION ................... 3 Functionality and Features of the 100BASE-T1 MediaConverter_BCM ... 3 Warranty and Safety Information ................ 4 Declaration of conformity ..................5 HARDWARE INTERFACES ..................6 Connectors ......................6 2.1.1 Black MQS Connector ................... 6 2.1.2 RJ45 Ethernet connectors ................7 Other Interfaces ....................
1 GENERAL INFORMATION 1.1 Functionality and Features of the 100BASE-T1 MediaConverter_BCM Figure 1—1: 100BASE-T1 MediaConverter_BCM The Technica Engineering 100BASE-T1 MediaConverter_BCM transmits data frames directly from the physical layer BroadR-Reach (100BASE-T1) to Fast Ethernet (100BASE-TX) with constant delay time of 2.0µs. Features: •...
General Information: Power requirement: 8 to 16 Volt DC (nominal 12 Volt DC) Power consumption: 2 Watt Size: 92 x 63 x 30 mm Weight: 0,2 kg International Protection: IP 2 0 Operating temperature: -40° to +80 °Celsius LINKS: The User can download the latest firmware and documentation for the 100BASE-T1 MediaConvert_BCM here: https://technica-engineering.de/produkt/100base-t1-mediaconverter_bcm/ 1.2 Warranty and Safety Information...
2 HARDWARE INTERFACES 2.1 Connectors On the label on top of the device you can see an overview about all HW-Interfaces of the 100BASE-T1 MediaConverter_BCM. Figure 2—1: Label of 100BASE-T1 MediaConverter_BCM with pinning information 2.1.1 Black MQS Connector The pinning of the ECU connectors is listed on the label on top of the device as well. (See Figure 2—1).
The Tyco Electronics (TE) Micro Quad Lock System (MQS) is used. Name Picture Part Number Tyco, MQS Abdeckkappe 2x9 Pol, black 1-967416-1 Alternative 1-1355350-1 Tyco, MQS Buchsengehäuse 2x9 Pol 965778-1 Alternative 962108-2 Tyco crimp contact 928999-1 Table 2—1: Parts of black MQS connector Note: You can use the official Tyco tool for these crimp contacts.
2.2 Other Interfaces 2.2.1 DIP-Switches The 100BASE-T1 MediaConverter_BCM has two DIP-Switches for configuration (see Chapter 3). 2.2.2 Status LEDs The 100BASE-T1MediaConverter_BCM has two status LEDs at the frontside of the case for the 100BASE-T1 Port. Upper LED: Green Color. It is lit when there is a linkup on the 100BASE-T1 port. Lower LED: Yellow Color.
3 CONFIGURATION OF THE DEVICE The 100BASE-T1 MediaConverter is configured by two DIP-Switches on the front of the device. DIP-Switch Status Description ON (up) 100BASE-T1 Port is set to Master OFF (down) 100BASE-T1 Port is set to Slave ON (up) 100BASE-T1 Port is set to FullOut OFF (down) 100BASE-T1 Port is set to HalfOut...
4 100BASE-T1 FILTER There are different BroadR-Reach Filter in different Hardware versions of the 100BASE- T1 MediaConverter_BCM: The following BR-Filter is used in the Hardware version 3.0: In Version 3.0 the Würth CMC 510010003 is used for L32. In Version 3.0a the TDK CMC ACT45L - 2 01 - 2P is used for L32. Figure 4—1: BR-Filter for HW v3.0 and v3.0a The following BR-Filter is used in the Hardware version 2.0: Figure 4—2: BR-Filter for HW v2.0...
5 ADDITIONAL INFORMATION • The 100BASE-T1 MediaConverter_BCM is optimized for automotive use. The maximum cable length for 100BASE-T1 segments is limited to 15 meters 100BASE-T1 MediaConverter_BCM User Manual...
6 LIST OF FIGURES Figure 1—1: 100BASE-T1 MediaConverter_BCM ............. 3 Figure 1—2: Declaration of conformity ................5 Figure 2—1: Label of 100BASE-T1 MediaConverter_BCM with pinning information ..6 Figure 4—1: BR-Filter for HW v3.0 and v3.0a ..............10 Figure 4—2: BR-Filter for HW v2.0..................10 100BASE-T1 MediaConverter_BCM User Manual...
7 CHANGELOG Version Chapter Description Date First release Rework of design and update of all information 21.09.2018 100BASE-T1 MediaConverter_BCM User Manual...
8 CONTACT If you have any questions regarding this product, please feel free to contact us: Technica Engineering GmbH Leopoldstr. 236 80807 München Germany Fax: +49-89-34290265 Info@technica-engineering.de www.technica-engineering.de 100BASE-T1 MediaConverter_BCM User Manual...