ü
The parameter settings at the start of this inspection test are assumed to be
factory default settings. If this is not the case, the inspection test may not be
successful even though there is nothing wrong with the servo amplifier or motor.
Also, at the conclusion of the test, some amplifier parameters may not be
ü
Damage during shipment could cause erratic motion or a run-away condition.
Therefore the motor should be securely held down during this test and no load
During this Inspection Test you will use the Remote Operator to change parameters and
jog the motor. If you have any trouble, refer to the Maintenance and Troubleshooting
chapter on page 100. If you still have difficulty, refer to page 9 for details on the various
methods for contacting the Technical Support team.
1.
Wire 230Vac to the r and t terminals of the servo amplifier terminal block.
2.
Wire 230Vac to the R, S, and T terminals of the servo amplifier terminal block and
earth ground to á
Connect the motor power cable to the U, V, W and á terminals of the servo amplifier
3.
using the supplied cable.
4.
Connect the encoder to the servo amplifier CN2 connector using the supplied cable.
5.
Connect the Remote Operator to the OP connector on the servo amplifier.
6.
If the motor has a brake, apply the specified 24Vdc to release the brake.
s
Holding Brake
Power Supply
Servo Motor
Copyright © 2000 Automation Intelligence, Inc.
WARNING
returned to the initial state.
WARNING
should be attached to the shaft.
Servo Amplifier
n
r
230 VAC
OP
t
o
R
S
230 VAC
T
á
p
CN2
U
Power
V
Cable
W
á
q
Feedback
Cable
14
r
Remote
Operator
Issued: 27-Apr-00