Cable Gland Installation - Hayward AquaRite + Owner's Manual

Hide thumbs Also See for AquaRite +:
Table of Contents

Advertisement

Name
Description
Filter Pump
Filtration pump control
Aux 1
Auxiliary voltage output (for contactor switching control)
pH
Peristaltic acid pump
Light
Lighting control (One {1} LED light only)
Aux 3
Auxiliary dry contact
Aux 4
Auxiliary dry contact (or heating control).
If no heating system is installed on Aux 4, it can be used as another auxiliary contact. To do this, contact Hayward technical support.
Name
Description
FL1
T-Cell Flow detection switch
Spa/Cover
Spa flow detection
(Optional accessory - available with the Hayward Spa Flow Switch Upgrade
Kit)
o C/ o F
Temperature probe
(Optional accessory - available with the Hayward Temperature Probe
Upgrade Kit)

Cable Gland Installation

In order to ensure watertight wire connections to the PCB through the AquaRite+ enclosure, wire cables are to be secured with the black
cable glands supplied. The two (2) cable glands supplied with the chlorinator are for the Cell Flow Switch and any Light connections.
Gland
1.
Insert the cable into the domed end of the
gland and pull through.
3.
Tighten gland with a spanner whilst still
holding the nut to secure the gland in place.
Note:
Use the gland location holes in the bottom of the unit before the sides to ensure all cables are pointing downward.
Description of Outgoing Relays
Description of Inputs
Cable
Tighten
USE ONLY HAYWARD
Terminals
Socket Outlet
Nut
Mounting
Frame
2.
Hold the nut against the hole on the inside
of the mounting frame. Push the cable and
gland into the hole whilst simultaneously
rotating to screw the nut on to the thread.
4.
Pull the cord through the gland until the
intended input point can be reached.
Secure and seal the cord in place by
fastening the domed cap with a spanner
until firm.
®
GENUINE REPLACEMENT PARTS
Type of output
240 V a.c.
1 - 2
240 V a.c.
3 - 4
SELV 24 V a.c.
5 - 6
SELV 12 V a.c.
7 - 8
Dry contact
9 - 10
Dry contact
Terminals
Type of output
B - C
SELV 12 V
A - C
SELV 12 V
F - G - H
Tighten
Max Load
7 A
1 A
1 A
50 W
1 A
1 A
-
Page 9