Wall Mounted Installation
The AquaRite+ must be installed a minimum 3.5 m horizontal distance (or more, if required by local regulations) from the pool, within 1 m
of an RCD protected general purpose outlet and within 4.5 m from where the T-Cell will be installed. The unit must be placed vertically on a
flat surface, with the cables downwards. As the unit enclosure is also used to evacuate heat (heat dissipation from internal components),
it is important that the four sides of the unit remain unobstructed. Do not to install the AquaRite+ behind a panel or in an enclosed space.
See the Wall Mounting Installation Template at the centrefold of this guide (between pages 10 -11) and use as an aid to drill accurate
holes for the installation.
Before installing the control unit in the intended location, check that the power cord can reach the protected outlet and that the cell cable
can reach the intended T-Cell location. Installation must be performed in accordance with Local/State/Federal Government codes and the
latest edition of the AS/NZS 3000 Wiring Rules.
IMPORTANT:
enclosure until the screws are firm. Use of a power tool will strip the threads out of
the plastic.
Plumbing Installation
Disconnect the pool filtration pump before starting the installation and remove pressure from the system.
The flow switch must be installed on the return pipe directly in line with the T-Cell and the liquid acid injection point (if optional pH Upgrade
Kit is used). Allow a 30 cm straight section before the flow switch if it is mounted in position 1 below. If it is mounted in position 2 below, then
the T-Cell can be counted as the 30 cm straight section of pipe.
The flow switch must be installed with the arrows on it pointing in the direction of water flow to ensure that it is tripped by the water flow
during filter pump operation. The T-Cell can also be mountd verticle as long as the water enters the cell from the bottom to keep it flooded
during operation.
(See page 6 for a comprehensive diagram of the AquaRite+ system with the optional accessories.)
Check
Valve
IMPORTANT:
ONLY use a hand screwdriver to fasten the mounting lugs to the
Wires to
AquaRite+
40 cm
30 cm
Flow
Switch
Position 1
Return Pipe
There must be at least a 30 cm straight pipe run before (upstream) the Flow Switch.
®
USE ONLY HAYWARD
Flow
Switch
Cell
Position 2
GENUINE REPLACEMENT PARTS
pH Kit
Injection
Point
(Optional)
Back to
Spa
Back to
Pool
Page 5