CDHD
o1 5
Plu s 1 5 V Ou t of Ran ge
o15
D e fin it ion
Type
Act ive disa ble
M e ssa ge #
D e scr ipt ion
Act ion r e qu ire d
o- 1 5
M inu s 1 5 V Ou t of Ra n ge
o- 15
D e fin it ion
Type
Act ive disa ble
M e ssa ge #
D e scr ipt ion
Act ion r e qu ire d
o5
5 V Ou t of Ra n ge
o5
D e fin it ion
Type
Act ive disa ble
M e ssa ge #
D e scr ipt ion
Act ion r e qu ire d
User Manual
Displayed in sequence
Plus 15V Out of Range
Fault
Yes
FLT 36
The int ernal + 15 V supply is out of range.
This fault disables t he drive.
The drive probably needs repair. Cont act Technical
Support .
Displayed in sequence
Minus 15V Out of Range
Fault
Yes
FLT 37
The int ernal -15 V supply is out of range.
This fault disables t he drive.
The drive probably needs repair. Cont act Technical
Support .
Displayed in sequence
5V Out of Range
Fault
Yes
FLT 52
5V is low or powering off.
This fault disables t he drive.
May occur during power off. I f it occurs under ot her
condit ions, cont act Technical Support .