To Assign User Codes And Attributes - ADT Security Manager 3000 User Manual

Adt safewatch pro 3000 security manager 3000 security system user's guide
Hide thumbs Also See for Security Manager 3000:
Table of Contents

Advertisement

The following lists the various command strings for adding user codes and attributes.
Refer to the User Setup chart at the back of this manual for factory assignments of user
attributes and to keep a record of user programming.
NOTE: Partition Programmer code can be used only for user numbers assigned to that
programmer's partition.
Add User Code:
( Users 03/33 are preset
to partition programmers,
but can be changed.)
Delete User Code:
Authority Level:
Access Group:
User's Partition:
Factory Assignments:
Part. 1 = users 03-32
Part. 2 = users 33-49
RF User Number:
Pager On/Off:
Master/Part. Prog.code + [8] + user no. + new user's code
User 01 = installer
User 02 = master
The Touchpad beeps once to confirm that new user was added.
Master/Part. Prog. code + [8] + [user no.] + [#] [0]
The user code and all attributes* programmed for this user number,
including any associated RF keys, are erased from the system.
(*except assigned partition)
Master/Part. Prog. code + [8] + [user no.] + [#] [1]+ auth. level
Authority Levels (see definitions on previous page):
0 = standard user
1 = arm only
2 = guest
Master/Part. Prog. Code + [8] + [user no.] + [#] [2]+ group (1-8)
You can assign users to a group, then set an access schedule that
defines the times this group of users can operate the system. The
system ignores these users outside the scheduled times.
Master Code + [8] + [user no.] + [#] [3]+ partition(s) + [#]
Use this command to assign the partitions the user can access. Enter
partition numbers sequentially, then press [#] to end the entry.
Users can operate any combination of partitions desired.
Partition Numbers:
0 = clears part. 1 and part. 2 assignments
1 = partition 1
Master/Part. Prog. Code + [8] + [user no.] + [#] [4]+ zone no.
Use this command to assign a wireless button device (keyfob) to this
user (keyfob must be enrolled in system first; see installer).
Zone number: enter the zone number assigned to a button on the
keyfob that will be used for arming/disarming by this user.
Master/Part. Prog. Code + [8] + [user no.] + [#] [5] + 0 or 1
You can program a user so that a message is sent to a pager
whenever this code is used to arm or disarm the system.
Paging On/Off: 1 = allow paging; 0 = no paging for this user
User 03 = partition 1 programmer
User 33 = partition 2 programmer
3 = duress
4 = partition programmer
2 = partition 2
3 = common partition
(to end)