Chapter9 Voltage Rise/Fall Time Test
TIME:VOLTage:LOW <Voltage>
This command is used to set the
measuring the rise time of voltage output.
Command Syntax
TIME:VOLTage:LOW <Voltage>
Parameters
0 through MAX|MINimum|MAXimum|DEFault
Unit
V
Returned Parameters
MINimum
Query Syntax
TIME:VOLTage:LOW?
TIME:VOLTage:LOW?
This command is used to query the start rising voltage value.
Command Syntax
TIME:VOLTage:LOW?
Parameters
None
Returned Parameters
<NRf>
TIME:VOLTage:HIGH <Voltage>
This command is used to set the
when measuring the fall time of voltage output.
Command Syntax
TIME:VOLTage:HIGH <Voltage>
Parameters
0 through MAX|MINimum|MAXimum|DEFault
Copyright © ITECH Electronic Co., Ltd.
Voltage Rise/Fall Time Test
start rising voltage value
starting drop voltage value
of the load when
of the load
56