. . . . . PLATEN QTM ERROR
RESTART PRINTER
ERROR LOG display: PLATEN QTM ERROR
Detection sensor: Platen thermistor
The temperature value of a platen is abnormal (under _20 dC or more than 100 dC).
Contents:
Possible cause:
1. The platen thermistor or the related harness is defective.
(Refer to "4-7. Temperature Detection".)
. . . . . ROOM QTM ERROR
RESTART PRINTER
ERROR LOG display: ROOM QTM ERROR
Detection sensor: Room thermistor
The temperature value inside this unit is abnormal (under _20 dC or more than 100 dC).
Contents:
Possible cause:
The room thermistor or the related harness is defective. (SE-929 board)
(Refer to "4-7. Temperature Detection".)
. . . . . MARK ALARM
RESTART PRINTER
ERROR LOG display: MARK ALARM
Detection sensor: Ribbon mark sensor
Contents:
The difference between the high- and low-level potentials of a ribbon mark sensor
during printing is under 0.25 V.
Possible cause:
1. The ribbon mark sensor block is dirty due to dust.
2. The ribbon mark sensor or the related harness is defective. (LE-352 board, SE-934
board) (Refer to "4-6. Sensor Detection".)
. . . . . EDGE ALARM
RESTART PRINTER
ERROR LOG display: EDGE ALARM
Detection sensor: Paper edge sensor
Contents:
The difference between the high- and low-level potentials of an paper edge sensor
during printing is under 0.25 V.
Possible cause:
1. The paper edge sensor block is dirty due to dust.
2. The paper edge sensor or the related harness is defective. (LE-351 board, SE-933
board) (Refer to "4-6. Sensor Detection".)
. . . . . HEAD COOLING
PLEASE WAIT
Detection sensor: Head thermistor
The temperature of a thermal head becomes more than 63 dC while this unit is in the
Contents:
standby or printing state.
Possible cause:
1. The temperature of a thermal head becomes high during high-density printing or
during printing in a high-temperature environment. (Normal operation)
2. The filter of fan is dirty.
3. The thermal head cooling fan or the cooling fan for inside of the unit is defective.
(Refer to "4-3. Fan and Plunger Control".)