4.1
Maintenance
To ensure the correct function, safety and service life of the device the following points must be executed
in the maintenance interval.
Used only original spare parts, otherwise the warranty expires.
For all maintenance services the device must be completely shut down!!!
For all operations you have to make sure, that the device will not close unintended.
Danger of injury!!!
Pos : 24.3 /07 Wartung und Pfl ege/01 War tung/Wartung MECH ANISCH @ 0 \mod78_2.doc x @ 7151 @ @ 1
MECHNICAL
SERVICE INTERVAL
First inspection after
25 operating hours
After 50 operating hours
Minimum 1x per year
(at rough conditions shorten the
interval)
Pos : 24.4 /07 Wartung und Pfl ege/01 War tung/Wartung u. Pfleg e/Wec hs elautomati k @ 0\mod327_2.doc x @ 7193 @ @ 1
AUTOMATIC-RELEASE
Never grease the automatic-release, if necessary use oil!
Pos : 24.5 /07 Wartung und Pfl ege/02 Störungsbesei tigung/Ü _Stör ungsbesei tigung @ 0\mod25_2.doc x @ 7263 @ @ 1
13 / 15
Maintenance work
●
Control and tighten all screws and connections.
(The implementation is only allowed by an expert).
●
Tighten all screws and connections (take care that the tightening torques
according to the property class of the screws are observed).
●
Check all joints, bolts, guidance's and gears for correct function, if necessary
adjust or replace it.
●
Check all Grippers ( if available) for signs of wear.
●
Grease all slidings ( if available) when the device is in opened position with a
spatula.
●
Check of all the suspension parts, bolts and straps. Check for corrosion and safety
by an expert.