5.1.1.3 System Firmware Information

Menu Path:
[1] Operational Information & Status → [1] System Information → [3] System Firmware Information
Description:
Displays the current versions of the Controller Module Boot Firmware and the Controller Module Runtime
Firmware.

5.1.2 Hardware Status

Sections 5.1.2.1 through 5.1.2.7
including system temperature, status of the power module, information on fault system resets, parameters for
each switching module, parameters for each port, and Power On Self Test (POST) information.

5.1.2.1 System Temperature

Menu Path:
[1] Operational Information & Status → [2] Hardware Status → [1] System Temperature
Description:
Displays the current system temperature in both Celsius and Fahrenheit and the threshold temperature in Celsius.

5.1.2.2 Power Module Status

Menu Path:
[1] Operational Information & Status → [2] Hardware Status → [2] Power Module Status
Description:
Displays the status (either OK or NOT OK) of both the primary and secondary power modules. If the status is
NOT OK, complete the following steps:
1.
Check to make sure the power supply is inserted all the way into the chassis and that it is seated
correctly.
2.
Check the power cable in the back of the OptiStar EdgeSwitch to make sure it is properly connected.
3.
If the power supply is correctly inserted and the cable is properly connected, power down the OptiStar
EdgeSwitch and reinsert the power module. Power up again.
4.
If the power module status on the primary power supply is still NOT OK, switch the primary and
secondary power supplies, then contact technical support.
5 - 4
enable the user to display status information about the OptiStar EdgeSwitch,
Lucent Technologies
365-575-925R1.5
Issue 1, April 2002