Digitax F3 Plus Technical Manual page 42

Hide thumbs Also See for F3 Plus:
Table of Contents

Advertisement

Nr.  Functions 
See also Q.383 to Q.385 and Q.387. The allowed answer is either: 0 (No: Digitax protocol) or: 1 (Yes: custom protocol).
Enable LogIn/LogOut commands? - The questions Q.387 and Q.389 are very much related to each other. They deal with command execution in relation with th status of
387
being logged-in or logged-out. Their relationship is as follows:
Q.387
No
Yes
Yes
Yes
Yes
The varies items in the tabel have the following meaning:
Logged-In : is the status Logged-In? If No then the status is Logged-Out.
X : This can be either Yes or No; it has no importance.
The allowed answer is either:
Q 388 / Available for any possible software extension /
During LogOut mode reject commands? - The questions Q.387 and Q.389 are very much related to each other.
389
They deal with command execution in relation with the status of being logged-in or logged-out. Their relationship is as follows:
Q.387
No
Yes
Yes
Yes
Yes
The varies items in the tabel have the following meaning:
Logged-In : is the status Logged-
In ?
The allowed answer is either:
390
Enable Credit Card authorization numeric field?
391
Baudrate for COM 1: what is the baudrate (transmission-speed) of COM 1? The baudrate is given in baud with an accuracy of 1 baud.
The allowed value goes from 0 (min) to 65535 (max).
392
Maximum packet length for COM 1: what is the maximum length of a data-packet of COM 1? The packet length is given in byte with an accuracy of 1 byte. The allowed
value goes from 1 (min) to 512 (max).
393
Baudrate for COM 2: what is the baudrate (transmission-speed) of COM 2? The baudrate is given in baud with an accuracy of 1 baud.
The allowed value goes from 0 (min) to 65535 (max).
394
Maximum packet length for COM 2: what is the maximum length of a data-packet of COM 2? The packet length is given in byte with an accuracy of 1 byte. The allowed
value goes from 1 (min) to 512 (max).
395
First cost threshold for authorization: this is the first amount above which authorization is requested for acceptance of the payment of the fare with a credit-card. The cost
is given in the local currency with an accuracy of 1. The allowed value goes from 0 (min) to 1000000 (max).
396
Second cost threshold for authorization: this is the second amount above which authorization is requested for acceptance of the payment of the fare with a credit-card.
The cost is given in the local currency with an accuracy of 1. The allowed value goes from 0 (min) to 1000000 (max).
397
Third cost threshold for authorization: this is the third amount above which authorization is requested for acceptance of the payment of the fare with a credit-card. The
cost is given in the local currency with an accuracy of 1. The allowed value goes from 0 (min) to 1000000 (max).
398
Time-out for authorization of payment: this is the waiting-time during which authorization is requested for acceptance of the payment of the fare with a credit-card. If the
authorization is not obtained within this time then the request is considered denied. The waiting-time is given in seconds with an accuracy of 0.1 second. The allowed value
goes from 0.0 (min) to 6553.5 (max). The digit indicating multiples of 0.1 sec. (so at the right of the decimal point) will flash.
Time-Out keyboard locked: this is the time after which the keyboard gets unlocked (activated) automatically if WD-commands are not received anymore. As long as this
399
time has not passed the keyboard remains locked (not active).
This is valid for a time-out value of 1 or higher. A time-out value of 0 is a special case. In this case there is no time-out and the keyboard can only be unlocked by means of
an unlock-command (LM-command). See also paragraphs 2.1.2 (LM-command) and 2.1.22 (WD-command) of the commtax2 manual. The time is given in seconds with an
accuracy of 1 sec. The allowed value goes from 0 (min) to 255 (max).
Time out from trip start to accept forfait price.
400
Key bitmap enabled while the keyboard is blocked by overspeed
403
Tariff number to which are destinated all statistical memories calculated by the current block
404
Min. distance (in meters) which allows the trip to be saved (if less, tripp will be not considered)
405
Speed to block the keyboard of the taximeter: this is the speed above which the keyboard of the taximeter gets locked. As soon as the speed becomes less than this
406
threshold the keyboard gets unlocked again. Normally the value programmed here is a low speed like for example 10 Km/h. The speed is given in Km/h with an accuracy of 1
Km/h. The allowed value goes from 0 (min) to 255 (max). The value 0 is a special case. It means: disabled.
Speed to block the counting of the tariff: this is the speed above which the taximeter stops counting the tariff. As soon as the speed becomes less than this threshold the
407
taximeter continues counting the tariff again. Normally the value programmed here is a high speed like for example 140 Km/h. The speed is given in Km/h with an accuracy of
1 Km/h. The allowed value goes from 0 (min) to 255 (max). The value 0 is a special case. It means: disabled.
408
Block number if from Stopped back to Hired: this is the number of the block that will be used when passing from Stopped back to Hired.
The allowed value goes from 0 (min) to 62 (max).
409
Block number if from Stopped to ForHire: this is the number of the block that will be used when passing from Stopped to ForHire.
The allowed value goes from 0 (min) to 62 (max).
42
The information contained here are property of DIGITAX Automotive Electronics Italy, and extremely confidential. Any disclosure, copying, distribution to third 
Logged-In
Q.389
X
X
No
No
No
Yes
No
Yes
Yes
X
0 (No: Enabled) or:
Logged-In
Q.389
X
X
No
No
No
Yes
No
Yes
Yes
X
if No then the status is Logged-
cmd=LogIn : is the command a
Out.
Log-In command ?
0 (No: abort command) or: 1 (Yes: execute command (login only).
from Q 401 / Available for any possible software extension / to Q 402
party is strictly prohibited.
 
cmd=LogIn
Action
-
Normal operation without limits.
-
Execute command without answer.
No
Abort Command.
Yes
Change status to Logged-in.
-
Normal operation without limits.
cmd=LogIn - is the command a Log-In command?
- : this means that it doesn't apply.
1 (Yes: Disabled).
cmd=LogIn
Action
-
Normal operation without limits.
-
Execute command without answer.
No
Abort Command.
Yes
Change status to Logged-in.
-
Normal operation without limits.
X : this can be either Yes or
No; it has no importance.
 
Value 
1= Custom
No / Yes
- : this means that it doesn't apply.
No / Yes
No / Yes
0
baud
0 - 512
0
baud
1 - 512
1 - 1000000
0 - 1000000
0 - 1000000
0
seconds
0-255
0 - 65535
No / Yes
0-6
0-255
0-255
0-255
0 – 62
0 - 62
-
65535
-
65535
-
65535