Nr.  Functions 
answer is either:
160
Event Counter is momentarily suspended? - Event Counter 2 should be momentarily suspended? If not then it will be active.
The allowed answer is either:
161
Load-value Event-Counter n. 3: this is either the number of units, or the distance in metres, or the time in seconds, or the cost of the fare, or the cost of the extra charges
that should be counted for the tariff-block to be changed. The allowed value goes from 0 (min) to 65535 (max). The tariff-block to change to is to be programmed in Q.162.
162
Block-Number (abs) at event n. 3: this is the block number (absolute) to be used when the event occured that has been programmed in Q.161. The allowed value goes
from 0 (min) to 62 (max). Also allowed is the value 255; In this case, instead of using a new block number, the former block number is used again.
163
Block-Offset (rel) at event n. 3: this is the block offset (relative) to be used when the event occured that has been programmed in Q.161. The relative block offset is the
number of blocks to add to the current block number in order to obtain the new block number. The allowed value goes from 0 (min) to 62 (max).
164
Load-value is Units? - Is the parameter programmed in Q.161 for event counter 3 the number of units?
165
Load-value is Distance (in metres)? - Is the parameter programmed in Q.161 for event counter 3 the distance in metres?
166
Load-value is Waiting-Time (in seconds)? - Is the parameter programmed in Q.161 for event counter 3 the waiting-time in seconds?
167
Load-value is Cost of Fare? - Is the parameter programmed in Q.161 for event counter 3 the cost of the fare?
168
Load-value is Cost of Extra-Charge? - Is the parameter programmed in Q.161 for event counter 3 the cost of the extra-charge?
169
Reload every Metre? (if not: every Second) - Event Counter 3 must be reloaded every metre? If not then it will be reloaded every second.
The allowed answer is either:
170
Act. Only Above cross-speed? (if not: Allw.) - Event Counter 3 should be activated only above the cross-speed? If not then it will allways be activated. The allowed
answer is either:
0 (No: allways) or: 1 (Yes: only above).
171
Event Counter is momentarily suspended? - Event Counter 3 should be momentarily suspended? If not then it will be active.
The allowed answer is either:
172
Load-value Event-Counter n. 4: this is either the number of units, or the distance in metres, or the time in seconds, or the cost of the fare, or the cost of the extra charges
that should be counted for the tariff-block to be changed. The allowed value goes from 0 (min) to 65535 (max). The tariff-block to change to is to be programmed in Q.173.
173
Block-Number (abs) at event n. 4: this is the block number (absolute) to be used when the event occured that has been programmed in Q.172. The allowed value goes
from 0 (min) to 62 (max). Also allowed is the value 255; In this case, instead of using a new block number, the former block number is used again.
174
Block-Offset (rel) at event n. 4: this is the block offset (relative) to be used when the event occured that has been programmed in Q.172. The relative block offset is the
number of blocks to add to the current block number in order to obtain the new block number. The allowed value goes from 0 (min) to 62 (max).
175
Load-value is Units? - Is the parameter programmed in Q.172 for event counter 4 the number of units?
176
Load-value is Distance (in metres)? - Is the parameter programmed in Q.172 for event counter 4 the distance in metres?
177
Load-value is Waiting-Time (in seconds)? - Is the parameter programmed in Q.172 for event counter 4 the waiting-time in seconds?
178
Load-value is Cost of Fare? - Is the parameter programmed in Q.172 for event counter 4 the cost of the fare?
179
Load-value is Cost of Extra-Charge? - Is the parameter programmed in Q.172 for event counter 4 the cost of the extra-charge?
180
Reload every Metre? (if not: every Second) - Event Counter 4 must be reloaded every metre? If not then it will be reloaded every second.
The allowed answer is either:
181
Act. Only Above cross-speed? (if not: Allw.) - Event Counter 4 should be activated only above the cross-speed? If not then it will allways be activated. The allowed
answer is either:
0 (No: always) or: 1 (Yes: only above).
Event-Counter n.4 is moment. suspended? - Event Counter number 4 should be momentarily suspended? If not then it will be active.
182
The allowed answer is either:
At tariff-change discard accumul. Dist/Time? - If the tariff is changed manually with key K1 should the accumulated distance or time be discarded?
183
If not, the accumulated distance or time will be proportionaly accounted for. The allowed answer is either: 0 (No: account for) or: 1 (Yes: discard).
At tariff-change synchronize with next unit? - If the tariff is changed manually with key K1 should the current unit be completed with the current
184
parameters? If not, the tariff-change will be immediate. The allowed answer is either: 0 (No: immediate) or: 1 (Yes: synchronize).
Extra-Charge n. 4 is a discount? - Extra-Charge n. 4, as programmed in Q.27, should be interpreted not as an extra-charge but as a discount? The discount can only be
185
used as a percentage. Therefore the parameter of Q.31 should be programmed as Yes. The allowed answer is either:
In ForHire disable keys K1, K2, K3 and K4? - In ForHire the keys K1, K2, K3 and K4 should be disabled? In case of Yes the taxi-meter works normaly including the OP-
186
key but all functions that can be invoked with the keys K1, K2, K3 and/or K4 are inhibited.
The allowed answer is either:
Start-of-Fare time is used for Night/Holiday extras? - Should the time in which the fare starts be considered for the calculation of the night and/or holiday extras? In case
187
of Yes and if there is a change from night/holiday time to normal time (or vice versa) during the trip then for as long as the trip lasts the fare cost will be calculated as if it is
still night/holiday time. Starting from the next fare the parameters for normal time will be used.
The allowed answer is either:
Show fare and extra-charge divided by 100? - Should the fare and the extra-charge be shown on their resp. displays divided by 100?
188
In this way the two least significant digits (usually zero) are not shown. The allowed answer is either:
189
In case Night/Holiday extras are added on Flag drop, have to be added also on Min. trip amount?
190
On Euro conversion apply the Arround function?
191
The information contained here are property of DIGITAX Automotive Electronics Italy, and extremely confidential. Any disclosure, copying, distribution to third 
 
party is strictly prohibited.
0 (No: always) or: 1 (Yes: only above).
0 (No: active) or: 1 (Yes: suspended).
COUNTER N. 3
0 (No: every second) or: 1 (Yes: every metre).
0 (No: active) or: 1 (Yes: suspended).
COUNTER N. 4
0 (No: every second) or: 1 (Yes: every metre).
0 (No: active) or: 1 (Yes: suspended).
0 (No: enabled) or: 1 (Yes: disabled).
0 (No) or: 1 (Yes).
Available for any possible software extension
 
0 (No: extra-charge) or: 1 (Yes: discount).
0 (No: show normal) or: 1 (Yes: show divided by 100).
Value 
No / Yes
0 – 65535
0 - 62
0 - 64
No / Yes
No / Yes
No / Yes
No / Yes
No / Yes
No / Yes
No / Yes
No / Yes
0 - 65535
0 - 255
0 - 64
No / Yes
No / Yes
No / Yes
No / Yes
No / Yes
No / Yes
No / Yes
No / Yes
No / Yes
No / Yes
No / Yes
No / Yes
No / Yes
No / Yes
No / Yes
No / Yes
35