CAUTION: before you set the unit to 7.4 V it is essential to check that all consu-
mer units connected to the system - all servos, receiver, gyro, etc. - are expressly
approved for use with the higher voltage. Information on this matter can be found
in the instructions provided by the equipment manufacturers.
The output voltage setting can only be changed using the SensorSwitch. This is
the procedure for setting the output voltage:
- Switch the Gemini on using the SensorSwitch; both LEDs must light up green.
- Disconnect both batteries from the unit.
- Hold the SET button on the switch pressed in.
- Connect the batteries in turn while you continue to hold the SET button pressed
in.
- The LEDs on the switch now flash red three times if the unit is set to 7.4 V, or
green three times if set to 5.9 V. Check that both inputs display the same colour
when the batteries are plugged in.
- Release the Set button when you are sure that both LEDs have indicated the
correct setting.
The setting is a toggle action, i.e. if you wish to change the output voltage back to
5.9 V, simply repeat the procedure.