Removal Procedure Of Outdoor Unit - Gree KW09HQ3D6D Series Service Manual

Table of Contents

Advertisement

11.2 Removal Procedure of Outdoor Unit

18/24K
Steps
1.Remove handle
Twist off the screws used for fixing the handle and
v alve cover , pull the handle and v alve cover up
ward to remove it.
2.Remove top panel
Remove the screws connecting the top
panel with the front panel and left&right
side plate, and then remove the top panel.
3.Remove front side panel
Loosen the screws connecting the front side
panel and chassis. Remove the front side
panel.
78
Warning: Be sure to wait for a minimum of 20 minutes
after turning off all power supplies and discharge the
refrigerant completely before removal.
Procedure
front side panel
Service Manual
handle
valve cover
top panel
Installation and Maintenance