ELECTRICAL INSTALLATION

INSTALL ELECTRICAL BOX; Fig. 9
7
1. Drill a 2" diameter hole in the finished wall for the
conduit tube from the flush valve at the dimension
shown.
2. Cut a 105 x 105mm (4-1/8"x 4-1/8") opening in finished
wall for ELECTRICAL BOX (1) (not supplied) at the
dimensions shown.
Note: The ELECTRICAL BOX (1) can be installed in any
location along the marked arc.
3. Feed 27" EXTENSION CABLE (2) through wall opening
and back out through 2"diameter hole.
Important: Make sure the smaller end of the SENSOR
CABLE (2) goes through the 2" diameter hole.
4. Install ELECTRICAL BOX (1).
INSTALL POWER SUPPLY AND
8a
MAKE ELECTRICAL CONNECTIONS;
Fig. 10, 10a
Ensure that the line power to bathroom
CAUTION
is OFF prior to making connections.
1. Mount POWER SUPPLY (1) into ELECTRICAL BOX (2).
Connect White and Black power connections to
POWER SUPPLY (1). Fig. 10.
2. Connect AC POWER SUPPLY (1) to the single terminal
of the Y-ADAPTER (4). Fig. 10.
3. Connect one end of the 27" EXTENSION CABLE (3) to
one of the two available terminals of Y-ADAPTER (4).
Fig. 10.
4. After POWER SUPPLY (1) is installed and wire
connections are completed, install the COVER PLATE
FRAME (5) onto the ELECTRICAL BOX (2). Fig. 10a.
5. Install the two Tabs on the back side of the COVER
PLATE (6) into the two Slots located on the top edge of
the COVER PLATE FRAME (5). Push on bottom until it
snaps into place. Fig. 10a.
CAUTION: Use only American Standard
supplied cable sets. Using non-AS supplied
cables, or cutting, splicing or modifying any
components will void the warranty.
Fig.9 (TOP SPUD FIXTURE ILLUSTRATED)
305mm
(12" MAX.)
(51mm) 2" DIA.
HOLE FOR
2
CONDUIT
385mm
(15-1/8")
Fig.10
2
BLACK & WHITE
POWER
CONNECTIONS
Fig.10a
SLOT
5
2
5
Hubbel-RACO #256 OR EQUAL
(BY CONTRACTOR).
Hubbel-RACO 779
86mm
(3-3/8")
2
SUPPLY
(1" NPT)
1-1/2" TOP SPUD
3
4
1
CONNECTOR NOT USED
IN THIS INSTALLATION
(1" NPT)
SLOT
TABS
M965644 REV. 1.1 (12/14)
1
SMALL END
1
6