Download Print this page

KERN KFB-TAM Operating And Installation Instructions page 113

Display device

Advertisement

Available languages

Available languages

dUAL 2
P3 OTH
LOCK
s. Kap. 7.10 / 7.11
ANM
P4 tAr
Restricted taring
range
P5 St
St on
Follow up tare
St off
P6 SP
7.5, 15, 30
KFB/KFN-TAM-BA_IA-e-1832
Multi-interval balance
Weighing scales with one weighing range subdivided into partial
weighing ranges, each providing a different scale interval. The
scale interval depends on the applied load and is automatically
changed during loading and unloading.
COUNT
Display internal resolution
DECI
Position of the decimal dot
div 1
div.
div 2
CAP 1
CAP
CAP 2
noLin
CAL
LinEr
GrA
Not documented
on
Keyboard lock enabled
off
Keyboard lock disabled
on
Animal weighing enabled
off
Animal weighing disabled
,
Press
the current setting will be displayed. Using the
navigation buttons (see chap. 2.1.1) select the desired setting, the
active digit is flashing.
Confirm input by
.
Follow up tare switched on
Follow up tare switched off
Not documented
Readability [d] / verification value [e]
1. weighing range
Readability [d] / verification value [e]
2. weighing range
Weighing scale capacity [max]
1. Weighing range
Weighing scale capacity [max]
2. Weighing range
0
Adjustment, see chap.
Linearisation, see chap. 6.10
45

Advertisement

loading

This manual is also suitable for:

Kfn-tam