Operating Instructions
QJ 600-E
26. The safety chain must fit tightly to the load,
so that load with vacuum failure (e.g. due to
power failure) is held by the security chain.
28. Now the device with sucked load be transported to the destination.
29. Lower the load carefully (distance to the ground approx. 20 cm), then remove safety chain and
throw it under the load.
30. Never grip with the hands under load (stone slab)! Danger of squeezing!
31. Safety chain should be returned to chain case.
Put the device with the sucked load completely down on the floor.
●
The safety chain must never be used as a "lifting tackle" to attach the device (QUICKJET) on
the support frame (e.g. excavators)!
The duty cycle (lifting/venting) should not exceed 2/3 to 1/3.
Daily taking out of operation:
Before switching off the device with the push switch, allow it to run for at least 30 seconds with the
venting valve open .
This loosens and removes any dirt which may have been deposited on the vacuum blower.
6.2 Operation with HONDA power generator EU 20 i
Details see chapter „Installation HONDA- power generator EU 20 i", or attached HONDA-
operating instructions (GENERATOR EU 20i).
Pos : 25 /=============================== @ 0\mod8_2.doc x @ 5159 @ @ 1
22 / 25
Operation
27. The safety chain must never hang
loose under the load, otherwise load
may fall down, in a vacuum load failure
(e.g. due to power failure).
GB
Need help?
Do you have a question about the QUICKJET QJ-600-E and is the answer not in the manual?