Disassembly And Reassembly Of Applicator; Applicator Disassembly - Graco G-3S Instructions Manual

Swiveling applicator for robotic sealing applications
Table of Contents

Advertisement

Disassembly and Reassembly of Applicator

Applicator Disassembly

NOTE: Ensure a proper work bench with a vice with
"soft jaws" and access to compressed air are available
to facilitate the work.
1. The disassembly starts with removing the nozzle
head (BB). First remove the nozzle cap (BA). To do
this, unscrew the M6 hex button head screw (BE).
Then remove the nozzle cap with nozzles (BC).
Take care not to lose the nozzle gaskets (BD).
BE
BA
F
. 17
IG
2. Unscrew the three hex head screws (Allen screws)
that fixes the nozzle head to the front end of the
central body. If necessary, remove the nozzle head
packing at the front of the central body.
F
. 18
IG
3A5591D
BC
BD
BB
Disassembly and Reassembly of Applicator
3. With the nozzle head removed from the central
body, loosen the two screws and take away the lock
ring and washer.
F
. 19
IG
4. Slide off the swivel chamber with connection hous-
ing.
F
. 20
IG
17