Address Setting; Setting Of Plc I/O Connector Numbers; Setting Of I/O Unit Addresses - Panasonic S-LINK V User Manual

Flexible wire-saving system
Hide thumbs Also See for S-LINK V:
Table of Contents

Advertisement

The S-LINK V system uses one controller to send up to 512 points (512 points × 2 for
NOTE
SL-VVMES2) (256 nodes) of signal in the serial transmission mode.
To clarify the sent-from and sent-to units, assign a number to each I/O device.
These numbers are referred to as 'addresses.'
To properly operate the S-LINK V system, correctly set the addresses.

Setting of PLC I/O connector numbers

CAUTION
Be careful not to set the same address for the PLC I/O connectors.
Considering the set connector numbers, set the optimum I/O control points for the controller.
For the address setting examples, refer to page 176.
Using the connector number setting switches, you can set a connector number consisting of 32 points for each PLC
I/O connector. (The same connector number setting method can be used for any types of PLC I/O connectors.)
For the connector number setting examples, refer to page 73.

Setting of I/O unit addresses

CAUTION
● Be careful not to set the same address for the S-LINK V I/O units.
● Set the addresses of S-LINK V I/O units while observing the I/O area set by the PLC I/O connectors.
Note that any address exceeding the I/O control points cannot be set.
Using the address setting switches, assign addresses to I/O units.
For each I/O unit, the assigned address will be the first number of the address, and the rest of the address will
be set depending on the specified number of I/O points.
For a detailed description, refer to page 74.
● When using the picking switch SL-VPK0□
To assign the address, use the address setting remote controller SL-VAR1 and send it to the SL-VPK0□.
For a detailed description, refer to the User's Manual that came with the address setting remote controller
SL-VAR1.

Address Setting

33