Flexible Wire-saving Link · S-LINK V
PCI Bus S-LINK V Control Board
SL-VPCI
Instruction Manual

Advertisement

loading

Summary of Contents for Panasonic S-LINK V

  • Page 1 Flexible Wire-saving Link · S-LINK V PCI Bus S-LINK V Control Board SL-VPCI Instruction Manual CMJE-SLVPCI No.0062-88V 2018.3 panasonic.net/id/pidsx/global...
  • Page 2 ● S-LINK V system is not compatible with system. ● Please refer to “S-LINK V User's Manual” for details of the system design. ● Any protective devices or safety circuits against system malfunction should be designed to be external to the system.
  • Page 3: Functional Description

    7) BUSY indicator (Orange) 6) Transmission indicator (Green) 5) System setting button (Green) 2) Board No. setting switches 18.42 1) S-LINK V terminal block connector View from wiring side Terminal Remarks F.G. Frame ground +24V External power supply input +24V...
  • Page 4 Setting is read in only once when power is supplied to the computer. Changing the mode switch setting during operation is ineffective. (The setting cannot be changed with the reset command on the S-LINK V system side.) Transmission mode setting switch...
  • Page 5 8) Error indicator (Red) It lights up when an error occurs on the S-LINK V system main cable. In case the cause of the er- ror is eliminated, it blinks, and if the error No. is cleared with program, or when the system setting is done, it turns OFF.
  • Page 6 Transmission mode / I/O control point HML0 + 41 I/O setting HML0 + 44 HML0 + 45 S-LINK V I/O unit connected node number HML0 + 46 HML0 + 47 Not usable (= 04) HML0 + 48 Error No. / Error state...
  • Page 7 1) HML0 + 00 to HML0 + 3F: Data area Relationship between “Computer I/O address” and “S-LINK V address” S-LINK V address Computer I/O address (hexadecimal) bit 7 bit 6 bit 5 bit 4 bit 3 bit 2 bit 1...
  • Page 8 When each bit is “1,” the S-LINK V I/O unit having the set address is connected on the main cable. Note: When an S-LINK V I/O unit has several I/Os, only the bit corresponding to the first address of that unit is “1.”...
  • Page 9 Note: In case of S-LINK V I/O (Bank number = 00H) and interruption setting (Bank number = 07H), the internal circuit maintains the condition even if switches to other bank.
  • Page 10 Address 496 to 511 0: Input, 0: Output 4) HML0 + 45, HML0 + 46: S-LINK V I/O unit connected node number It shows the number of nodes to which S-LINK V I/O units are connected. (0 to 256 nodes)
  • Page 11 It is used for checking if the output data is sent to S-LINK V output unit. In case data is sent to the same address at an interval shorter than the S-LINK V system response delay time, the data may not be transmitted. After the output data is written, if “1”...
  • Page 12 3: “System set” It reads in the S-LINK V I/O unit connection state at that time. If “1” is written into HML0 + 49 bit 3, HML0 + 4A bit 3 turns to “1” after the completion of system setting.
  • Page 13 0: If the input signal is changed, “Input hold” selects whether the changed condition is main- tained or not. (Usable for S-LINK V address 0 to 7 only. However, if hold is used at one address, then all 0 to 7 are held.) If bit 0 is “1,” even when the input signal is changed, the condition is maintained until “0”...
  • Page 14 bit 3: “Error interruption” sets whether an interruption occurs or not when an error occurs. When bit 3 is “1” an interruption occurs, and when bit 3 is “0” the interruption does not occur. In case the error interruption is set to effective, the interruption occurs with OR operation applied to all error occurrences.
  • Page 15: Specifications

    [PCI bus side] +5V DC ±5% [+24V DC] 85mA or less (Note 2) Current consumption [+24V DC (power supply for S-LINK V I/O units and load)] Max. supply current: 7A (Note 3) [+5V DC] 315mA or less Transmission speed A mode: 110kbps, B mode: 27.5kbps, C mode: 6.9kbps Connection method “T”...
  • Page 16 ● During the above mentioned period, if a failure of the product occurs under normal use and opera- tion, and if Panasonic Industrial Devices SUNX determines that it is responsible for the failure, it shall repair the defect or replace the product. However, in no event shall Panasonic Industrial De-...