Function Selection
The sensor can detect a test rod wherever it is in the detection zone. In other words, when a test rod is
inserted into the detection zone, the stable-state indicators (STB) turn off and the ON/OFF output-state
indicators turn red.
When the external test function is used:
ON/OFF-state indicators turn red when the test input line is open or short-circuited to 0 V to 1/2 Vs.
When the external device monitoring function is used:
When the F3SJ-B-01TS is blocked and the external device monitoring input terminal is open, it enters a
lockout state.
-Checking that Hazardous Parts Stop While the Machine Operates
The hazardous parts stop immediately when a test rod is inserted into the detection zone at three posi-
tions: "directly in front of the emitter", "directly in front of the receiver", and "between the emitter and
receiver". (Use the appropriate test rod.)
The hazardous parts remain stopped as long as the test rod is in the detection zone.
The hazardous parts stop when the power of the F3SJ-B-01TS is turned OFF.
The actual response time of the whole machine is equal to or less than the calculated value.
Maintenance Checklists
To ensure safety, keep a record of the inspection results. When the user is a different person from those who
installed or designed the system, he/she must be properly trained for maintenance.
Checklists
-Inspection at Startup and When Changing Operators
There is no approach route other than through the detection zone of the F3SJ-B-01TS.
Part of the operator's body always remains in the detection zone of the F3SJ-B-01TS when working
around the machine's hazardous part.
The actual safety distance is equal to or greater than the calculated value.
There must be no dirt on or damage to the optical surface and spatter protection cover (F39-HB
sold separately) of the F3SJ-B-01TS.
ON/OFF-state indicators turn red when the test input line is open or short-circuited to 0 V to 1/2 Vs.
The test rod is not deformed.
When the power of the F3SJ-B-01TS is turned ON while nothing is in the detection zone, it must operate
as follows:
The power indicator and ON/OFF-state indicators turn green within 2 seconds after the F3SJ-B-01TS is
turned ON.
Nothing should exist in the detection zone and stable-state indicators must turn ON at power on.
The test rod is detected when it is moved around in the detection zone as shown in the diagram of Pre-
Operation Checklists. In other words, when a test rod is inserted into the detection zone, the stable-state
indicators (STB) turn off and the ON/OFF-state indicators turn red.
Neither connector nor bracket must be loose.
-Checking that Hazardous Parts Stop While the Machine Operates
The hazardous parts are movable when nothing is in the detection zone.
The hazardous parts stop immediately when a test rod is inserted into the detection zone at three posi-
tions: "directly in front of the emitter", "directly in front of the receiver", and "between the emitter and
receiver". (Use the appropriate test rod.)
The hazardous parts remain stopped as long as the test rod is in the detection zone.
11
Wiring
Mounting/Beam Alignment
Start
Stop
Pre-Operation Checklist /
Maintenance Checklists
□□□□
,
F3SJ-B-01TS
Quick Installation Manual